If the sensor is connected to a display / programming unit
it is supplied with operating voltage by this unit,
it continuously transfers its data to this unit (measured values, signals
transferred to the evaluation electronics and parameter settings).
It provides the following options:
Remote display
Indication of the current system pressure (in bar, PSI, MPa or kPa)
by an LED display.
Remote evaluation
2 output signals are provided (or 1 signal in the Teach mode)
according to the set output configuration.
Remote Teaching
setting to current system pressure by Teach function
Programming / remote programming of the sensor
Parameters can be set before the sensor is mounted and set up or
during operation.
For programming: operating instructions of the programming
unit.
For use of the sensor with PP2000 prior to installation of the sensor:
Use a suitable power supply (operating voltage 11,1 ... 30 V DC).
23
ENGLISH
3Sensor with display/programming unit PP2000
L-
L
+
OU1
OU2 / IN (Teach)