The default settings for the display brightness in energy-saving mode and the status LED in en-
ergy-saving mode can be changed via IO-Link.
The switch to energy-saving mode may only take effect after a delay of 30 seconds.
For the setting ECO.m = OFF, the general Display brightness
49
and Status LED
50
settings apply.
11.4.9.1 Parameter setting via the device keys: Energy-saving mode
Go to EF > CFG > ECO.m.
Set ECO to activate the energy-saving mode.
Set OFF to deactivate the energy-saving mode.
11.4.10 Lock / unlock
The unit can be locked electronically to prevent unauthorised setting.
This lock prevents the settings from being changed via the keys on the unit.
Factory setting: not locked.
If the device is locked via the IO-Link interface, it can only be unlocked via IO-Link.
11.4.10.1 Parameter setting via unit keys: lock / unlock
Locking:
Make sure that the unit is in the normal operating mode.
Press
▲
+
▼
simultaneously for 10s until Loc is displayed.
The device is locked for parameter setting via the device keys. When trying to change a parameter val-
ue, the symbol Loc appears in the digital display.
The locking can only be removed via the device keys. Changing the parameter setting is still
possible via the IO-Link interface.
Unlocking:
Make sure that the unit is in the normal operating mode.
Press
▲
+
▼
simultaneously for 10s until uLoc is displayed.
The locking of the device keys is removed.
11.4.11 Reset the device
The device can be reset in two ways.