PG17xx Electronic manometer
30 © ifm electronic gmbh 11601190 / 01 07 / 2025
Simulation menu SIM and ‘reset device’ menu rES:
BACk
[EF]
OU1
CFG
OU2
DIS
DIA
SIM
RES
S.Tim
S.On
S.PRS
BACk
[SIM]
----│OL│UL*│DEAC
S.diA
n.DIA│Err│COMP│SC│OL.T│UL.T
12│3│451015│20│30│4560
On│OFF
BtB
APPL
BACk
[RES]
no│YES
no│YES
Main menu
Fig.11: UL is only available for the PGxxx6 devices; PGxxx7, PGxxx8.
Parameter Explanation
S.PRS Simulated pressure value in simulation mode
S.diA No diagnostic case simulated (= n.DIA); error (= Err); Component error (= COMP); short
circuit (= SC); internal temperature exceeded (= OL.T); internal temperature not reached
(= UL.T).
S.Tim Duration of the simulation in minutes
S.On Starts the simulation mode
APPL Application reset (reset of application-specific parameter settings)
BtB Back-to-Box reset (reset to factory settings)