IFM PG1705 handleiding

55 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 48 van 55
PG17xx Electronic manometer
48
This function is only available via the IO-Link interface.
10.6.6 Device status
The device continuously monitors itself during operation and provides the results of its self-diagnosis
in the following ways:
Via the status LED and the text in the digital display (Ò Warning messages/52).
The current device status and a list of past events are displayed via the IO-Link interface.
10.7 Service functions
10.7.1 Device information
Unalterable device information is stored on the unit. This includes:
Product name
Manufacturer
Manufacturer ID
Device ID
Serial number
Hardware / firmware revision
Description
In addition, further freely definable tags with a maximum length of 32 characters can be assigned to
the unit via the IO-Link interface using suitable parameter setting software. This includes:
application-specific tag
function tag
location tag
10.7.2 Optical localisation
The sensor can be located remotely in the system via the IO-Link interface.
If the command is used, the following appears in the device display:
The digital display shows "IO-L”.
The switching status LED, the LEDs below the digital display providing additional information and
the LED ring all flash green simultaneously.
This function is only available via the IO-Link interface.
10.7.3 Simulation
This function is used to simulate process values or error states and check the sensor behaviour.
The following values can be simulated:
process values for pressure and temperature within the measuring range.
process values outside the measuring range (UL, OL).
diagnostic states (e.g. device fault, short circuit).