MFH2xx Pressure-resistant position sensor for hydraulic cylinders
14 © ifm electronic gmbh 11660562 / 00 06 / 2025
8 Electrical connection
The unit must be connected by a qualified electrician.
Observe the national and international regulations for the installation of electrical equipment.
Voltage supply according to SELV, PELV.
Disconnect power.
Connect the unit as follows:
43
2 1
L
1
2
3
4
OUT2
L+
OUT1 / IO-Link
Fig.12: Wiring diagram
Pin Assignment
1 L+
3 L-
4 (OUT1) switching output or IO-Link
2 (OUT2) Switching output
L
1
2
4
3
L+
1
L
1
2
4
3
L+
2
Fig.13: Circuit examples
1: 2 x positive switching
2: 2 x negative switching