Pressure-resistant position sensor for hydraulic cylinders MFH2xx
© ifm electronic gmbh 11660562 / 00 06 / 2025 13
7 Installation
2
1
1: Device
2: Welding bush
The device can be adjusted to the piston rod via the insertion depth.
Do not screw in the device too deeply to avoid mechanical damage to the device, piston rod
and cylinder.
For installation with a fixed end stop, use devices from the M9H series.
2
3
2
1
3
1: Device
2: Piston rod
3: Piston with switching cam
Make sure that the piston rod is in the end position to be detected.
Screw the device up to the end stop.
Unscrew the device half a turn (~ 0.5 mm) to avoid mechanical damage.
Tighten the fixing nut (tightening torque
data sheet).
For fine adjustment, also note the following: Fine adjustment of the end position