IFM LT3922 handleiding

36 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 11 van 36
Electronic sensor for level and temperature LT39xx
11
I [mA] / U [V]
L
A
20 / 10
4 / 0
I [mA] / U [V]
Fig.5: [ou2] = [I] or [U]
I [mA] / U [V]
L
A
20 / 10
4 / 0
I [mA] / U [V]
Fig.6: [ou2] = [InEG] or [UnEG]
A: Active zone
L: Level
[MEdI] = [Auto] or [OP] = [OFF]: Operating mode with the lowest operational reliability!
4.7.3 Temperature monitoring
u [SEL2] = [TEMP]
For temperature measurement the analogue signal can be scaled. The limits of the measuring range
for the lower output signal (analogue start point = ASP2) and the upper output signal (analogue end
point = AEP2) can be set.
Minimum distance between [ASP2 ] and [AEP2 ]= 22 °C.
If the measuring range is not reached or is exceeded by more than 10%, [UL] / [OL] is
displayed.
Output function current output: