LT39xx Electronic sensor for level and temperature
10
u [OP] = [value ...] (Overflow prevention OP activated!)
u [ou2] = [InEG] or [UnEG]
I [mA] / U [V]
L
20 / 10
4 / 0
A
OP
Fig.3: OP positioned in the upper segment.
I [mA] / U [V]
L
20 / 10
4 / 0
A
OP
Fig.4: OP shifted downward
A: Active zone
OP: Measuring segment overflow prevention OP
L: Level
The measuring range is limited by the active measuring segment OP. If the level reaches the
measuring segment OP, the output signal jumps to its minimum value (4mA / 0V).
The position of the measuring segment OP does not have any influence on the gradient of the
curve.
4.7.2 Level measurement without overflow prevention
u [SEL2] = [LEVL]
u [OP] = [value ...] (Overflow prevention OP activated!)
u [ou2] = [I] or [U]