IFM DTI921 handleiding
Handleiding
Je bekijkt pagina 33 van 46

DTI801 DTI901 DTI911 DTI921
33
Byte
Process data output when
starting the write operation
Process data output during
data transmission
Process data input
11 EPC 7 Data 9 0x00
12 EPC 8 Data 10 0x00
13 EPC 9 Data 11 0x00
14 EPC 10 Data 12 0x00
15 EPC 11 Data 13 0x00
16 EPC 12 Data 14 0x00
17 EPC 13 Data 15 0x00
18 EPC 14 Data 16 0x00
19 EPC 15 Data 17 0x00
20 ignored Data 18 0x00
21 ignored Data 19 0x00
22 ignored Data 20 0x00
23 ignored Data 21 0x00
24 ignored Data 22 0x00
25 Memory Bank Data 23 0x00
26 Address High Data 24 0x00
27 Address Low Data 25 0x00
28 Length High Data 26 0x00
29 Length Low Data 27 0x00
30 Block counter Block counter Block counter
31 ignored ignored Error value
9.9.1 Example "WRITE DATA”
The example demonstrates the successful writing of data (command “0x07”, EPC “0x7134”).
Command
value
EPC length
EPC 0 to 15
Memory
bank
Address
Length
Data 0to27
Block
counter
Status bit
“Cmd Start”
Command
value
Data 0to27
Block
counter
Error value
Status bit
“Cmd End”
Status bit
“Cmd Start”
Process data output image Process data input image
Preset com-
mand
0x00 0x00 0x00
00
0x00 0x00
00
0x00
00
0x00 0x00 0 0x00 Sin-
gle
EPC
0x00 0x00 0 0
Controller
sets com-
mand (write
40 bytes to
address
0x10)
0x07 0x02 0x71
34
0x03 0x00
10
0x00
28
0x00 0x00 1 0x00 Sin-
gle
EPC
0x00 0x00 0 0
Device ac-
knowledges
command
0x07 0x02 0x71
34
0x03 0x00
10
0x00
28
0x00 0x00 1 0x07 0x00 0x00 0x00 0 1
Controller
transfers the
first data
0x07 Data for ID tag 0x01 1 0x07 0x00 0x00 0x00 0 1
Device ac-
knowledges
data
0x07 Data for ID tag 0x01 1 0x07 0x00 0x01 0x00 0 1
Bekijk gratis de handleiding van IFM DTI921, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | IFM |
Model | DTI921 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3980 MB |