IFM CR3121 handleiding
Handleiding
Je bekijkt pagina 11 van 24

ISOBUS gateway CR3121
11
Visualisation
example:
1
2
3
4
5
6
1
2
3
4
1
2
3
4
5
6
7
9
10
8
12
11
Page 1
1
2
3
4
5
6
1
2
3
4
1
2
3
4
5
6
7
9
10
8
12
11
Data Mask 2
8.2.2 Issuing warnings
The function module FB_Warnings issues warning symbols as well as acoustic warnings.
The input parameter wIconWarning<n> defines the type of warning symbol.
The input parameter byStateIcon<n> defines the colour of the warning symbol:
• 0 = white (e.g. off)
• 1 = green (e.g. on)
• 2 = yellow (e.g. warning)
• 3 = red (e.g. alarm)
The input parameter xAcusticWarning switches the acoustic warning on/off. If the acoustic warning
is switched on, the following signal tones are possible:
• If at least one input parameter byStateIcon<n> has the value 2, a warning tone will sound.
• If at least one input parameter byStateIcon<n> has the value 3, an alarm tone will sound.
Bekijk gratis de handleiding van IFM CR3121, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | IFM |
| Model | CR3121 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 2483 MB |







