8.2.2 Issuing warnings
The function module FB_Warnings issues warning symbols as well as acoustic warnings.
The input parameter wIconWarning<n> defines the type of warning symbol.
The input parameter byStateIcon<n> defines the colour of the warning symbol:
0 = white (e.g. off)
1 = green (e.g. on)
2 = yellow (e.g. warning)
3 = red (e.g. alarm)
The input parameter xAcusticWarning switches the acoustic warning on/off. If the acoustic warning
is switched on, the following signal tones are possible:
If at least one input parameter byStateIcon<n> has the value 2, a warning tone will sound.
If at least one input parameter byStateIcon<n> has the value 3, an alarm tone will sound.