AL1433 IO-Link master with EtherCAT interface
14
6.5 IO-Link ports (class B)
IO-Link devices (sensors, actuators) are connected to the IO-Link ports (class B).
The IO-Link ports meet the requirements of the IO-Link specifications 1.0 to 1.1.2.
The ports are equipped with short-circuit detection (US, UA).
The connected IO-Link devices must be supplied exclusively via the IO-Link master.
The additional digital output at pin 2 of the ports meets the requirements of utilisation category DC-13
according to standard IEC 60947-5-1, 20W.
Wiring:
3
1 2
4
5
1: Sensor supply L+ (US)
2: Digital output / Actuator supply L+ (UA)
3: Sensor supply L- (US)
4: C/Q IO-Link
5: Actuator supply L- (UA)
6.5.1 Connecting IO-Link devices (class B)
u Connect the IO-Link devices to ports X1...X4. Maximum cable length per port: 20 m.
u For connection, use M12 connectors (minimum protection rating: IP 65 / IP 66 / IP 67 / IP 69K).
u Tighten the cable plug using 1.3 ± 0.1Nm.
6.5.2 Connecting IO-Link devices (class A)
CAUTION
Connection of IO-Link devices (class A) to IO-Link ports (class B) with 4 or 5-pole
connectors
w Risk of fire
w Malfunction
u To connect IO-Link devices (class A) to IO-Link ports (class B), use 3-pole connectors
only!
u Observe the IO-Link Design Guideline:www.io-link.com.
u Connect the IO-Link devices to ports X1...X4. Maximum cable length per port: 20 m.
u For connection, use M12 connectors (minimum protection rating: IP 65 / IP 66 / IP 67 / IP 69K).
u Tighten the cable plug using 1.3 ± 0.1Nm.
6.6 Ground connection
The FE potential is connected to the following points of the device:
Upper mounting lug of the housing
Ports XD1 and XD2: Pin 5 (FE)
Ports XF1 and XF2
To ensure the protection of the device against electrical interference and to ensure the safe
function of the device, the housing has to be connected to the GND of the installation using the
shortest possible route.
u Ground the device via the mounting screw of the upper mounting lug.