Icron Polaris 7044 handleiding
Handleiding
Je bekijkt pagina 15 van 24

15
DESCRIPTION ACCOUNT LEVEL COMMAND EXAMPLES
SET RS232 Control
- Cannot be
performed through
RS232 Interface
Admin SETCONTOL<space>SERIAL<space><
STATE>
States:
1 = RS232 Control on
0 = RS232 Control off
Response:
SETCONTROL-SERIAL-<state>
Command:
SETCONTROL SERIAL
1<CR><LF>
Response:
SETCONTROL-SERIAL-
1<CR><LF>
SET NETWORK
Control – Cannot be
performed through
network API
Admin SETCONTOL<space>IP<space><STA
TE>
States:
1 = RS232 Control on
0 = RS232 Control off
Response:
SETCONTROL-IP<state>
Command:
SETCONTRO SERIAL
1<CR><LF>
Response:
SETCONTROL-IP-1<CR><LF>
Query Control Admin CONTROL<space>-?
Response:
CONTROL-SERIAL-1
CONTROL-IP-1
Control:
Serial – RS232
IP – Network
State:
1 – Control On
0 – Control Off
Command:
CONTROL -?<CR><LF>
Response:
Response:
(if Serial Control is enabled, no
display if disabled)
CONTROL-SERIAL-1
(if Network Control (SSH) is
enabled, no display if disabled)
CONTROL-IP-1
RESPONSE User/Admin Automatic Response to attempt to
control Matrix via RS232 or API when
GUI active
NAK<CR><LF>