14 Troubleshooting
220 Exsis I/T - 01/23-1 - EHG-0027-02EN
Fault
Cause
Remedy
Refrigerator does not re-
frigerate in gas operation
Lack of gas
Connect a full gas bottle
Open regulator tap and
gas isolator tap
Air in the gas pipe
Switch appliance off and
start it up again (if neces-
sary, repeat procedure
3 to 4 times)
Refrigerator does not re-
frigerate in 12 V operation
Fuse is defective
Replace fuse
Battery is discharged
Check and charge battery
Ignition switched off
Switch on ignition
Heating element is defec-
tive
Contact customer service
Refrigerator does not re-
frigerate in 230 V opera-
tion
Fuse is defective
Change fuse; switch fuse
on again at fuse box
No 230 V power supply
Connect 230 V power
supply
Heating element is defec-
tive
Contact customer service
Refrigerator changes into
gas mode in spite of
mains connection
Line voltage too low
Check line voltage (refrig-
erator will automatically
change into 230 V opera-
tion in case of correct line
voltage)
14.7.2 Thetford N 3000 E/A
For certain faults, indicators also flash on the operating panel.
Fault
Cause
Remedy
LEDs for types of energy
and display of the temper-
ature range flash
Refrigerator does not work
Switch the refrigerator off
and on again
Check availability of an
energy source
LED " " and LEDs for
display of the temperature
range level are flashing
No 230 V power supply
Connect 230 V power
supply
230 V automatic circuit
breaker has triggered
Switch on 230 V auto-
matic circuit breaker
230 V operating voltage
too low
Have the 230 V power
supply checked by an au-
thorised specialist work-
shop