Troubleshooting 14
Exsis I/T - 01/23-1 - EHG-0027-02EN 219
14.6 Air conditioning unit
Fault
Cause
Remedy
Air conditioning unit does
not cool
No 230 V power supply
Connect 230 V power
supply
Fuse is defective
Check fuse and replace if
necessary
Temperature below 16 °C
-
Temperature has been set
incorrectly
Adjust the temperature
Air filter contaminated
Replace air filter
14.7 Refrigerator
14.7.1 General
In the event of a defect contact the nearest customer service workshop of
the relevant appliance manufacturer. The list of addresses is enclosed with
the accompanying appliance documentation. Only authorised qualified per-
sonnel may repair the appliance.
Further information can be obtained in the manufacturer's instruction
manual.
Fault
Cause
Remedy
Refrigerator does not re-
frigerate sufficiently
Insufficient ventilation of
unit
Check if ventilation grills
are covered; remove co-
vers if necessary
Remove ventilation grills
and clean the space be-
hind them (of leaves etc.)
Thermostat adjusted too
low
Adjust higher value on
thermostat
Cooling fins heavily iced-
over
Check if refrigerator door
closes correctly
Too many warm foods
stored in a short period of
time
Let warm foods cool down
before storage
Appliance has not been
running long enough
Check again after 4 or
5 hours if the refrigerator
cools
Ambient temperature is
too high
Remove the ventilation
grills periodically
The vehicle is not in a
horizontal position
Set the vehicle up in a
horizontal position