Electrical system 8
Exsis I/T - 01/23-1 - EHG-0027-02EN 121
8.6.3 Battery monitor
You must fully recharge a discharged living area battery as soon as pos-
sible.
The battery monitor in the transformer/rectifier monitors the voltage in the
living area battery.
If the voltage of the batteries falls below 10.5 V, the battery monitor in the
transformer/rectifier switches off all the 12 V appliances.
◼ Switch off all electrical appliances that are not absolutely essential at the
corresponding switch.
◼ If necessary, use the 12 V main switch to switch the 12 V power supply
back on for a short while. This is only possible, however, when the bat-
tery voltage is above 11 V. If the voltage is below this level, the 12 V
power supply cannot be switched on again until the living area battery
has been recharged.
8.6.4 Charging the battery
When the vehicle engine is running, a relay in the transformer/rectifier alter-
nator switches on the living area battery and the starter battery together and
recharges them with the vehicle generator. When the vehicle engine is
switched off, the batteries are automatically disconnected from one another
again by the transformer/rectifier. This prevents the starter battery from be-
ing run down by electrical appliances in the living area. The starting capabil-
ity of the vehicle is thus preserved. The terminal voltage of the living area
battery or the starter battery can be read on the panel.
If the vehicle is connected to the 230 V power supply via the CEE socket
outlet, the living area battery and the starter battery are charged by the
charger module on the transformer/rectifier. The starter battery is only
charged with a float charge. The charging current is adapted to suit the
charging condition of the battery. This ensures that it is not possible to over-
load the battery.
To make use of the maximum output from the charger module on the trans-
former/rectifier, switch off all electrical appliances during charging.
8.6.5 Retrofitting additional 12 V appliances
The electrical system in the living area of the vehicle may be equipped with
optional devices. The optional devices are to be connected to the reserve
outputs on the transformer/rectifier. The output of the optional devices may
not exceed the rating of the fuse (e.g. 15 A). Do not use fuses on the trans-
former/rectifier that are higher than those stated on the transformer/rectifier.
Measures: