Hymer BMC-T (2023) handleiding

286 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 146 van 286
8 Electrical system
146 B-MC I/T - 01/23-1 - EHG-0016-03EN
The following tables will help you to correctly interpret the battery voltage
display.
Battery voltage
(values during
operation)
Mobile operation
(vehicle moving,
no 230 V connec-
tion)
Battery operation
(vehicle station-
ary, no 230 V con-
nection)
Power operation
(vehicle station-
ary, 230 V con-
nection)
Notes regarding the bat-
tery voltage
Less than 11 V
Danger of total dis-
charge
No charging via the
alternator
If appliances are
switched off: Bat-
tery flat
No charging via the
transformer/rectifier
12 V power supply
overload
If appliances are
switched on: Bat-
tery overload
12 V power supply
overload
11.5 V to 13 V
No charging via the
alternator
1)
Normal range
No charging via the
transformer/recti-
fier
1)
12 V power supply
overload
1)
12 V power supply
overload
1)
13.5 V or more
Battery being
charged
Occurs only briefly
after charging
Battery being
charged
1)
If the voltage does not exceed this range for several hours.
Values for off-load voltage
Charging condition of the battery
Less than 12 V
Totally discharged
12.2 V
25 %
12.3 V
50 %
More than 12.8 V
100 %
Total discharge causes irreparable damage to the battery.
Measure the off-load voltage preferably several hours after the previous
charging (e.g. in the morning) and not directly after a current drain.

Bekijk gratis de handleiding van Hymer BMC-T (2023), stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHymer
ModelBMC-T (2023)
CategorieNiet gecategoriseerd
TaalNederlands
Grootte31425 MB