8 Electrical system
146 B-MC I/T - 01/23-1 - EHG-0016-03EN
The following tables will help you to correctly interpret the battery voltage
display.
Battery voltage
(values during
operation)
Mobile operation
(vehicle moving,
no 230 V connec-
tion)
Battery operation
(vehicle station-
ary, no 230 V con-
nection)
Power operation
(vehicle station-
ary, 230 V con-
nection)
Notes regarding the bat-
tery voltage
Less than 11 V
Danger of total dis-
charge
No charging via the
alternator
If appliances are
switched off: Bat-
tery flat
No charging via the
transformer/rectifier
12 V power supply
overload
If appliances are
switched on: Bat-
tery overload
12 V power supply
overload
11.5 V to 13 V
No charging via the
alternator
1)
Normal range
No charging via the
transformer/recti-
fier
1)
12 V power supply
overload
1)
12 V power supply
overload
1)
13.5 V or more
Battery being
charged
Occurs only briefly
after charging
Battery being
charged
1)
If the voltage does not exceed this range for several hours.
Values for off-load voltage
Charging condition of the battery
Less than 12 V
Totally discharged
12.2 V
25 %
12.3 V
50 %
More than 12.8 V
100 %
Total discharge causes irreparable damage to the battery.
Measure the off-load voltage preferably several hours after the previous
charging (e.g. in the morning) and not directly after a current drain.