HTW -MO5-120IX41B2R32 handleiding

182 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 49 van 182
INSTALLATION MANUAL
47
MULTI SPLIT IX21D5MULTI SPLIT IX21D5
4. ESPECIFICATIONS
TABLE 4.1
Number of units that can be used
together.
Connected units 1-5 units
Compressor stop/start frequency Downtime 3 min or more
Power supply voltage
Voltage uctuations ±10% relative to nominal voltage
Voltage drop during startup ±15% relative to nominal voltage
Interval imbalance ±3% relative to nominal voltage
TABLE 4.2
1 Drive
2
1 Drive
3
1 Drive
4
1 Drive
5
Maximum length for all rooms
40/131 60/197 80/262 80/262
Maximum length for an indoor unit
25/82 30/98 35/115 35/115
Maximum height difference between
indoor and outdoor unit
15/49 15/49 15/49 15/49
Max height difference between the
indoor units
10/33 10/33 10/33 10/33
10m(32.8ft)
Indoor unit
Indoor unit
Indoor unit
Outdoor unit
15m(49ft)
15m(49ft)