INSTALLATION MANUAL
42
MULTI SPLIT IX21D5
0. SAFETY PRECAUTIONS
CAUTION when using R-32 refrigerant
1.- Installation (space)
• That the installation of pipes is kept to a minimum.
• That the pipes are protected from physical damage.
• That the national regulations regarding gas are complied with.
• That the mechanical connections are accessible for maintenance.
• Where mechanical ventilation is required, ventilation openings should be kept free of obstructions.
• When disposing of the product, national regulations and the appropriate process must be followed.
• The appliance should be stored in a well-ventilated area where the size of the room corresponds to
the area of the room as specied for operation.
• Spaces where refrigerant pipes must comply with national gas regulations.
2.- Revisiones
• Any person involved in the maintenance or repair of a refrigerant circuit must have a current valid
certicate issued by an industry-accredited testing body, certifying their tness to handle refrigerants
safely in accordance with an approved testing specication. the industry.
• Reviews will only be performed as recommended by the equipment manufacturer. Maintenance
and repairs requiring the assistance of other qualied personnel should be performed under the
supervision of the person competent in the use of ammable refrigerants.
3. Do not use means to accelerate the defrosting process or to clean other than those recommended
by the manufacturer.
4. The equipment should be stored in a room without continuously operating ignition sources
(for example: open ames, gas appliances or electric heaters running).
5. Do not puncture or burn the device.
6. Please note that coolants may be odorless.
7. Make sure that foreign materials (oil, water, etc.) do not enter the pipes. Additionally, when you store pipes,
securely seal the opening by pressing the ends together, taping them, etc.
For indoor units, use only the R-32 threadless joint set when connecting the unit interior and pipes (when
connected indoors). The use of pipes, normal nuts or nuts ares other than those specied, may cause
product malfunction, breakage in pipes or injuries due to the high internal pressure of the refrigerant cycle
caused by air ow.
8. The equipment must be installed, operated and stored in a room with an area larger than X m
2
(Please see the form below). The equipment should not be installed in unventilated environments with
a surface area less than Xm
2
(Please see the following form).