REQUIREMENTS FOR OPERATION
REQUIREMENTS FOR OPERATION
Requirements for Operation, Service and Installation of Appliances Using
Flammable Refrigerants
Recovery
– When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good
practice that all refrigerants are removed safely.
– When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are
employed. Ensure that the correct number of cylinders for holding the total system charge is available. All
cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i. e. special
cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated
shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before
recovery occurs.
– The recovery equipment shall be in good working order with a set of instructions concerning the equipment
that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable,
FLAMMABLE REFRIGERANTS. In addition, a set of calibrated weighing scales shall be available and in good
working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using
the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult
manufacturer if in doubt.
– The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the
relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
– If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable
level to make certain that FLAMMABLE REFRIGERANT does not remain within the lubricant. The evacuation
process shall be carried out prior to returning the compressor to the suppliers. Only electric heating to the
compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be
carried out safely.
IMPORTANT
NOTE: This air conditioner is designed to be operated under condition as follows and performance may be
reduced outside of these operating temperatures.
NOTE FOR 1H09HN2DAA, 1H12HN2DAA,1H18HN2DAA AND 1H24HN2DAA MODELS:
To achieve optimal capacity and efficiency at 5°F (-15°C) and below it is recommended to operate indoor fan in
Turbo Mode.
NOTE FOR ALL OTHER MODELS: To achieve most efficient operation, operate the indoor unit with fan speed
in Auto mode. In Cooling mode, use a set temperature of 78°F (25.5°C) or higher. In Heating mode, use a set
temperature of 73°F (22.5°C) or lower.
Operating Range
Cooling 14°F~115°F(-10°C~46°C)
Heating* -15°F~75°F(-26°C~24°C)
*For heat pump models only.