I. Startup
WARNING
All parts are factory-adjusted. Improper adjustments may adversely affect safety,
performance, component life, and warranty coverage.
NOTICE
• If the unit is turned off, wait for at least 3 minutes before restarting the unit to
prevent damage to the compressor.
To prevent damage to the water pump seal, do not leave the control switch in the
"PUMP" position when the water tank is empty.
At startup, conrm that all internal and external connections are free of leaks.
The remote condensing unit must have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
1) If removed, replace the splash curtain, front frame, and all panels except the front panel
in their correct positions. See Fig.18. If not already removed, remove the front panel.
Fig. 18
Pump Suction Hose
Drain Pipe
Water Tank Drain Hose
Float Connection Hose
Splash Curtain
Evaporator Case Wall
Water Tank
Front Frame
Bin Control
Insulation Panel
Front Panel
2) Open the water supply line shut-off valve.
3) Move the mode switch on the control box to the "ICE" position, then move the control
switch to the "ON" position.
4) Turn on the power supply, and allow the water tank to ll with water and the icemaker to
operate for a total of 10 minutes.