TROUBLESHOOTING
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at 22
TW75_230V | TW150_230V
once a week
•
Srcew connections •
Check, tigthen if necessary
if required
• Cleaning fluid
• change
• Filter
• Clean, change
Changing the cleaning fluid
• Remove the drain plug on the bottom of the vat
• Allow all the cleaning fluid to drain into a suitable collection
container
• Close the drain plug
• Fill with fresh cleaning fluid
• Dispose of old cleaning fluid according to manufacturer's
instructions
16.3 Storage
Store the machine in a dry, frost-proof and lockable place when not in use. Disconnect the
machine from the power supply. Make sure that unauthorised persons and especially children do
not have access to the machine.
NOTE
Improper storage can damage and destroy important components. Only store packed
or already unpacked parts under the intended ambient conditions!
16.4 Disposal
Observe the national waste disposal regulations. Never dispose of the machine,
machine components or operating equipment in the residual waste. If necessary,
contact your local authorities for information regarding available disposal options.
If you purchase a new machine or equivalent equipment from your specialist dealer, p22-he
is obliged in certain countries to dispose of your old machine properly.
TROUBLESHOOTING
WARNING
Danger due to electrical voltage!
Handling the machine with connected power supply may result in serious injury or
death.
Disconnect the machine from the power supply before starting work to
eliminate defects!
Allow all the cleaning fluid to drain into a suitable collection container.
Many possible sources of error can be eliminated in advance if the machine is properly connected
to the power supply.
If you are unable to carry out the necessary repairs properly and/or do not have the required
training, always consult a specialist to solve the problem.
Trouble
Possible cause
Solution
Pump does not pump
• Switch or pump defective
• repair or change
•
Flexible tube dirty
•
clean
Cleaning fluid is not moved
evenly
• Pump is not completely covered
with cleaning fluid
• Cover the pump completely
with cleaning solution
Vat cover does not stay open
• Vat cover bent
• Cover stay defectiv
• Check cover bent and cover
stay, repair or change if
necessary