Holzmann SK90 handleiding
Handleiding
Je bekijkt pagina 24 van 31

OPERATION
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at 24
SK90_230V
14.3 Electrical connection
WARNING
Dangerous electrical voltage!
Risk of injury due to dangerous electrical voltage!
The machine may only be connected to the power supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
• Check, whether the supply voltage and the frequency correspond to the specifications of
the machine.
NOTE
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
• Use a supply cable that fulfils the electrical requirements (e.g. H07RN, H05RN) and take the
required cross-section of the supply cable from a current carrying capacity table. Pay
attention to the measures for protection against mechanical damage.
• Make sure that the power supply is protected by a residual current circuit breaker.
• Connect the machine only to a properly grounded outlet.
• When using an extension cable, make sure that the dimension matches the connected
load of the machine. The connection power can be found in the technical data, the
correlation of cable cross-section and cable lengths can be found in the technical literature
or obtain information from a specialist electrician.
• A damaged cable must be replaced immediately.
NOTE
Operation is only permitted with residual current device (RCD) with maximum
residual current of 30 mA.
14.4 Pneumatic connection
Connect the compressed air supply to the compressed air connector (1)
and set the working pressure according to the technical data.
The compressed air must be dry and oil-free.
OPERATION
Only operate the machine when it is in a perfect condition. Before each operation, a visual
inspection of the machine must be carried out. Safety devices, electrical and pneumatic lines and
operating elements must be checked carefully. Check screw connections for damage and tight fit.
15.1 Operating instructions
• Before use check the sealing performance.
• Do not aim the sandblast directly at hands, filter, hose or window.
• There are different blast medias for different tasks. Select the appropriate media. The table
below contains suggestions for different materials.
Material
Blast media
Material
Blast media
Wood
Corundum
Motor parts
Sode, nut shells
Aluminum, stainless steel
Glass beads
Stone, concrete
Nut shells
To make an exact selection, contact a blast media manufacturer directly.