Hobart PW12n-ADV handleiding
Handleiding
Je bekijkt pagina 34 van 116

– 34 –
Error
No.
Text On Screen Error Description Troubleshooting
038 Incoming Power to
Machine is Too High.
Machine Has Powered
Down.
The incoming voltage is
higher than the maximum
required machine voltage.
The incoming voltage must be at or below
the required machine voltage (see machine
data plate). Turn circuit breaker supply off and
ensure unit is connected with proper voltage
supply. Press Enter to clear error.
039 Fill Cycle Interrupted.
Close Door.
Door is opened during the
llcycle.
Close the door and ensure door is fully
seated.Thellcycleresumes.Iftheerrorper-
sists, contact Hobart Service.
049 Communication Between
the Controls Has Been
Interrupted.
Interruption of communica-
tion between control board
and touchscreen display.
Communication between the controls should
be automatically restored. If the problem per-
sists, contact Hobart Service.
052 Drain System Error.
Check Drain Pump and
Hose.
Wash tank water level is
above the upper limit.
Ensure power to machine is off and wash wa-
ter has cooled. Verify standpipe and bottom of
wash tank are free of debris. Clean the drain
hose and drain the machine. Ensure drain
hose is not kinked and installed properly. If
error remains on screen, press and hold the
power button for 5 seconds to clear the error.
Machine will drain and power down.
057 Wash Tank is Filling.
Cycle Will Begin When
Water is Replenished.
Wash tank water level is
low at start of wash cycle.
Machineautomaticallyllswhileerrorisdis-
played. Once proper water level is reached,
wash cycle will begin.
081 Final Rinse Thermistor
Error.
Final rinse temperature is
239°F (115°C) or greater.
Press and hold the power button for
5 seconds to clear the error. The machine
will drain and power off. If the error persists,
contact Hobart Service.
082 Final Rinse Thermistor
Error.
Final rinse temperature is
32°F (0°C) or lower.
Press and hold the power button for
5 seconds to clear the error. The machine
will drain and power off. If the error persists,
contact Hobart Service.
085 Wash Tank Overtemp
Tripped.
Wash tank overtemp has
been tripped.
Error cannot be cleared until overtemp has
been reset. Contact Hobart Service.
086 Booster Overtemp
Tripped.
Booster overtemp has been
tripped.
Error cannot be cleared until overtemp has
been reset. Contact Hobart Service.
088 Alert: Wash Tank Con-
tactor Fault. Pull Circuit
Breaker(s) and Contact
Service.
Wash tank heater remains
on while ignoring software
command to turn off.
Machineisrunningallanddraincycleto
protect the heater. This error is not user
serviceable. Turn circuit breaker supply(s) off
and contact Hobart Service.
089 Alert: Booster Contac-
tor Fault. Pull Circuit
Breaker(s) and Contact
Service.
Booster heater remains
on while ignoring software
command to turn off.
Machineisrunningallanddraincycleto
protect the heater. This error is not user
serviceable. Turn circuit breaker supply(s) off
and contact Hobart Service.
097 Detergent Supply Empty.
Replace Detergent.
Detergent has not been
sensed for two consecutive
cycles.
Ensure detergent is present in bottle and that
cap & tube are properly secured to bottle.
Replace detergent bottle if empty. Press the
ENTER button to clear the error.
098 Detergent Supply Empty.
Press Power Button to
Drain Machine and Power
Down.
Detergent has not been
sensed for two consecutive
cycles. The machine will be
locked out until the deter-
gent has been replaced.
Ensure detergent is present in bottle and that
cap & tube are properly secured to bottle.
Replace detergent bottle if empty. Press and
hold the power button for 5 seconds to clear
the error. The machine will drain and power
off. If the error persists, contact Hobart Service.
Bekijk gratis de handleiding van Hobart PW12n-ADV, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Hobart |
Model | PW12n-ADV |
Categorie | Vaatwasser |
Taal | Nederlands |
Grootte | 27655 MB |