Hobart PW12n-ADV handleiding

116 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 27 van 116
– 27 –
Parameter Name Description Possible Values Default Value
DELAY WASH PROGRAM
Enable/Disable
Enables or disables wash
tank temperature delay.
If enabled, wash cycle
will be delayed until mini-
mum wash temperature is
reached. Display will show
‘Heating’ until temperature
is reached.
Enable or Disable Disable
RINSE TEMPERATURE ALERT
Disabled
Disables low rinse temper-
ature alert.
Notication
Enables low rinse tempera-
ture alert. After set number
of cycles (default 3) below
minimum rinse temperature
requirement, display will
show rinse temperature
alert warning. The machine
will continue to function as
normal.
Lockout Machine
Enables low rinse tem-
perature lockout. After set
number of cycles (default
3) below minimum rinse
temperature requirement,
display will show rinse tem-
perature alert warning. The
machine will lockout and
unit will be inoperable.
Repeat Cycle
After set number of cycles
(default 3) below minimum
rinse temperature require-
ment, machine will auto-
matically repeat wash and
rinse cycles.
ENERGY SAVER MODE (-ADV & -ADVSW MODELS ONLY)
Energy Saver Mode
On Advansys machines,
this setting sets the time for
when the machine will turn
the heaters off to save en-
ergy when not being used.
Disabled
1 hour
2 hours
3 hours
2 hours