Error
No.
Text On Screen Error Description Troubleshooting
017 Wash tank pressure sensor
failure.
The minimum wash tank
water level has not been
reached. The machine will
not run.
Press and hold the power button for
5 seconds to clear the error. The machine
will drain and power off. If the error persists,
contact Hobart Service.
018 Wash tank water level is
too high.
Wash tank water level is
above the upper limit.
Press the ENTER button if displayed to clear
the error. If the ENTER button does not dis-
play, press and hold the power button for 5
seconds. Machine will drain and power off. If
the error persists, contact Hobart Service.
019 Tank strainer blocked.
Remove strainer, clean and
put back in place.
Tank strainer pan is
blocked.
Remove, clean and replace strainer pan.
Press the ENTER button to clear the error.
The machine will drain and power down if
the water level is low. If the water level has
returned to normal, the machine will power
off, but not drain. Power machine on to
continue operation.
020 Wash tank pressure sensor
error. Drain and restart
machine.
The wash tank water level
did not increase by the
anticipated amount after
cycle.
Press the ENTER button to clear the error.
The machine will drain and clear the error.
Ensure tank is clean. If the error persists,
contact Hobart Service.
021 Drain hose is clogged.
Clean drain hose and drain
machine again.
wash tank after drain cycle.
Ensure power to machine is off and wash
water has cooled. Verify bottom of wash
tank is free of debris. Clean the drain hose
and drain the machine. Ensure drain hose is
not kinked and installed properly. If error re-
mains on screen, press and hold the power
button for 5 seconds to clear the error. Ma-
chine will drain and power down.
022 Drain hose is clogged.
Clean drain hose.
During wash cycle, water
level not maintained at
normal level.
Ensure power to machine is off and wash
water has cooled. Verify bottom of wash
tank is free of debris. Clean the drain hose
and drain the machine. Ensure drain hose
is not kinked and installed properly. If error
remains on screen, press the ENTER button
to clear the error.
029 Program interrupted. Close
door.
Door is opened during ma-
chine operation.
Close the door and ensure door is fully
seated. The current operation resumes. If
the error persists, contact Hobart Service.
032 Fill error, inspect incoming
water line.
The booster water level did
not reach the proper level
within the set amount of
time.
Ensure incoming water supply is turned on
pressure is 15 - 65 psi. Press the ENTER
button to clear the error. If the error persists,
contact Hobart Service.