Hobart LXNR-2 handleiding
Handleiding
Je bekijkt pagina 14 van 32

– 14 –
Parameter Name Description Possible Values Default Value
DELAY WASH PROGRAM
Enable/Disable
Enables or disables wash
tank temperature delay.
If enabled, wash cycle
will be delayed until mini-
mum wash temperature is
reached. Display will show
‘Heating’ until temperature
is reached.
Enable or Disable Disable
RINSE TEMPERATURE ALERT
Disabled
Disables low rinse temper-
ature alert.
Enables low rinse tempera-
ture alert. After set number
of cycles (default 3) below
minimum rinse temperature
requirement, display will
show rinse temperature
alert warning. Machine
will continue to function as
normal.
Lockout Machine
Enables low rinse tem-
perature lockout. After set
number of cycles (default
3) below minimum rinse
temperature requirement,
display will show rinse
temperature alert warning.
Machine will lockout and
unit will be inoperable.
Repeat Cycle
After set number of cycles
(default 3) below minimum
rinse temperature require-
ment, machine will auto-
matically repeat wash and
rinse cycles.
STRAINER MONITORING
Strainer Monitoring
Detects if sump strainer
is in place through error
or warning. If set to Error
Message, unit is inoperable
until strainer is properly
installed. If set to Warning,
press Enter to continue
with normal machine
operation.
Error Message
Or
Warning
Error Message
* NOTE:
feature, ensure all machine panels and components are in place and that all facility connections to the machine (i.e.:
water, drain, electric) are in working order.
Bekijk gratis de handleiding van Hobart LXNR-2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Hobart |
| Model | LXNR-2 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 4923 MB |