1.
Immediately after connecting the appliance to the mains, touch key to switch on the appliance.
Then touch key for 3 seconds.
Menu appears and immediately followed by menu .
2.
Touch the key to open the Menu.
3. Use the and keys to select maximum appliance power.
The first number of the value shown is the number of phases connected, and the second and
third numbers indicate the current per phase.
4.
Touch key for 3 seconds to save the settings, or key if changes are not to be saved.
Number and
cross section of
Power cord
wires
Power cordPowerCurrentConnectionSettings
3 x 4.0 mm²H05VV-F7360 W1x32 A1 phase - 1 neutral132
3 x 1.5 mm²H05VV-F3680 W1x16 A1 phase - 1 neutral116
3 x 1.5 mm²H05VV-F2990 W1x13 A1 phase - 1 neutral113
3 x 1.5 mm²H05VV-F2760 W1x12 A1 phase - 1 neutral112
3 x 1.5 mm²H05VV-F2300 W1x10 A1 phase - 1 neutral110
4 x 1.5 mm²H05VV-F7360 W2x16 A2 phases - 1
neutral
216*
(default)
5 x 1.5 mm²H05VV-F7360 W2x16 A2 phases - 2
neutral (only for NL)
3 x 1.5 mm²H05VV-F7360 W2x16 A2 phases (BE)
4 x 1.5 mm²H05VV-F5980 W2x13 A2 phases - 1
neutral
213*
4 x 1.5 mm²H05VV-F5520 W2x12 A2 phases - 1
neutral
212*
4 x 1.5 mm²H05VV-F4600 W2x10 A2 phases - 1
neutral
210*
* Can also be used for a 3-phase connection where the 3rd phase is connected to (the unloaded)
terminal 3. For this connection, the supply cable must have 5 x 1.5 mm² cores.
16