Hisense 46VW25E handleiding

37 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 26 van 37
19
Serial Port State
:
When the serial port is open, the machine can receive serial
port commands sent by the external controller. See the table below for the specic
command protocol.
Data Parameters
DM-SERIES
Baud Rate 9600
Data length (bits) 8
Parity None
Stop bit 1
Flow control None
Command Format
PC -> TV:
Header
(2 Bytes)
Length
(2 Bytes)
Command
(4 Bytes)
Monitor ID
(1 Byte)
Data
(N Bytes)
Checksum
(1 Bytes)
End
(2 Bytes)
DD FF BB CC
TV -> PC:
Header
(2 Bytes)
Length
(2 Bytes)
Command
(4 Bytes)
Monitor ID
(1 Byte)
Data
(N Bytes)
Checksum
(1 Bytes)
End
(2 Bytes)
AB AB CD CD
[Note]
·
Length is the number of bytes of Command, Data and Checksum.
·
Checksum is XOR of Length, Command, Monitor ID and Data.
RS232
8

Bekijk gratis de handleiding van Hisense 46VW25E, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHisense
Model46VW25E
CategorieNiet gecategoriseerd
TaalNederlands
Grootte2422 MB