Hestan KRG484GD handleiding

24 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 24
©2021 Hestan Commercial Corporation
7
EN
CHANGING BURNER ORIFICES - RANGETOP SECTION
SIMMER ORIFICE
023698-XXX
MAIN ORIFICE
023690-XXX
.177 inch [4.5mm]
VENTURI /
AIR SHUTTER
THIS PORT TO
BE FULLY OPEN
DUAL-FLOW
BURNER BASE
ASSEMBLY
NOTE: ALIGN VENTURI / SHUTTER WITH 2nd GROOVE.
DIMENSION SHOWN FOR REFERENCE ONLY.
LOCK
SCREW
8. The main BURNER orifice can be replaced without disconnecting the hose. The simmer orifice hose
must be disconnected to access the orifice inside. See the chart on page 6 to select the appropriate
orifice for your gas type / altitude. The part numbers and identification (color / stamp) for the orifice are
given in the tables above.
The detail view shows the appropriate venturi / air-shutter dimension. The dimension is shown for
reference only in case the lock screw was loosened, or the flame characteristics are not correct and need
adjustment. If adjustment is needed, loosen the lock screw and adjust the air shutter in or out in very
tiny increments, lock down the screw, replace all the components and check the flame again.

Bekijk gratis de handleiding van Hestan KRG484GD, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.