Operation
Measurement details
For the greatest possible measuring accuracy, place the cable as precisely as possible in the
intersection of the markings between the pliers jaws.
Maximum input current: 100 A AC
Measuring range Resolution Tolerance (50-60 Hz)
2 A 1 mA ± 3 % + 10 digits
20 A 10 mA ± 2,5 % + 8 digits
100 A 100 mA ± 2,5 % + 5 digits
AC current
NCV
The NCV mode can be switched on with the NCV selection. In this mode, voltages can be
detected without contact. The tip of the clamp serves as a detecting sensor.
If no voltage is detected, the display shows "EF". If a voltage is detected, the display shows "-"
to "----". The closer you get to the detected voltage, the more dashes are shown in the display.
Maximum input voltage: 600 V AC | Input resistance: 10 MΩ
Measuring range Resolution Tolerance (45-400 Hz)
2 V 1 mV
± 1 % + 3 digits
20 V 10 mV
200 V 100 mV ± 1 % + 3 digits
VFC Mode ± 4 % + 3 digits
600 V 1 V ± 1,2 % + 3 digits
VFC Mode ± 4 % + 3 digits
AC voltage
Maximum input current: 100 A DC
Measuring range Resolution Tolerance
2 A 1 mA ± 2 % + 8 digits
20 A 10 mA ± 2 % + 3 digits
100 A 100 mA ± 2 % + 3 digits
DC current
To enter the DC current measuring range, press the "Select" key until "DC" is displayed. The
zeroing is carried out by a short press on the "ZERO" key.
Electrical energy may cause serious injuries!
Always wear personal protective equipment