5e. Control and power supply for lighting
1 Lighting.
2 Manual mode (ON/OFF).
3 Automatic mode: Starts up according to the time slots selected for the lighting.
The time slots can be congured with the following frequencies: daily, every
2 days, every 3 days, every 4 days, every 5 days, weekly, every 2 weeks, every
3 weeks, every 4 weeks.
4 LED light: If you are using a coloured LED light, go to the menu to congure
it. Colour selection: This menu allows you to change the colours manually and,
according to the type of LED light, program the pulse length required to cycle
through the colours and programs (by default, 0.5 s, maximum 10 s).
The unit supplies a voltage of 12 VAC 50W max.
Chlorine production is reduced by a third when the lighting is activated.
1 2 3 4 5
5f. Control of auxiliary relays
1 Auxiliary relays.
2 A maximum of four additional auxiliary relays
(water features, fountains, garden lighting, etc.)
can be controlled. This menu displays and allows
you to congure the relays that remain available
on your equipment.
3 Manual mode (ON/OFF).
4 Automatic mode: Starts up according to the
selected time slots. They can be congured with
the following frequencies: daily, every 2 days,
every 3 days, every 4 days, every 5 days, weekly,
every 2 weeks, every 3 weeks, every 4 weeks.
5 Timer mode: An operating time can be
programmed in minutes. Each time you press the
front panel key associated with the relay, it will be
activated for the programmed time. This function
is recommended for timing the operation of spa
blowers.
6 Relay name: It is possible to name the auxiliary
relays individually according to the associated
functions. To conrm, press OK.
1 2 3 4 5
6 6
6a. Installing and starting up the pH option
1
1
2
2 4 5
3
1 pH probe calibration: Recommended once a
month during the pool season.
2 Calibration using buffer solutions (buffer
solutions pH7 / pH10 / neutral). Follow the
instructions that appear on screen 3.
3 Calibration procedure involving 7 steps.
4 Manual calibration: Allows you to calibrate the
probes using 1 point (without buffer solution) –
recommended only for adjusting small deviations in
readings.
5 Without taking the probe out of the water, use
the Up/Down arrows to adjust the measurement
displayed so that it coincides with the reference
value (photometer or other measuring instrument).
1 Open the cover and connect the pH CHIP card to
the PH slot (see section 3C). The pH reading and
the Measures menu will be displayed automatically,
to congure the setpoint and carry out the
calibration.
2 Connect the dosing pump to the pH terminal using
a cable gland (see section 3C and 3D) and close
the cover.
3 Install the probe with its mount in the pipe and
connect the probe to the unit (see section 3D).
Follow the instructions for the pH pump to inject the
liquid.
• The probe has a lifetime of 1 year. We
recommend calibrating it every month during the
season the pool is in use.
Connecting the pH dosing pump
1 Connect the suction strainer: insert the
(transparent) PVC suction tube all the way into the
conical connector of the suction strainer, tighten the
clamping nut and position the suction strainer in the
bottom of the container holding the chemical to be
dosed.
2 Connect the suction and delivery tubes: loosen
the pump clamping nuts, insert the (transparent)
PVC suction tube on the left and the (opaque) PE
delivery tube on the right all the way into the conical
connector, and tighten the clamping nut.
3 Connect the injection valve: loosen the nut, insert
the (opaque) PE delivery tube all the way into the
conical connector, and tighten the clamping nut.
Screw the valve on to the mount provided on the
cell using Teon tape.
Operation of pH corrector dosing pump:
The pump starts up depending on the setpoint
entered in the menu Measures - Setpoints - acid
pH (setpoint < water pH). By default, the maximum
dosing time is 120 minutes to avoid acidication of
the water (AL3). The proportional method is used
for injection: 10 minutes ON (variable depending
on the difference between the measured value and
the setpoint) + 5 minutes OFF (xed). Both acid
and alkali can be dosed (contact your installer). The
pump is equipped with an on/off switch.
The Santoprene tube of the peristaltic pump has
a lifetime of 2 years. We recommend changing it
once a year.
Installing and preserving the pH probe:
1 The pH probe is “wet” packed and protected by
a plastic cap. The probes must always remain
wet. If the probes are allowed to dry, they will
be permanently unusable (not covered by the
warranty) and the pH test kit will be ineffective.
2 Remove the pH probe from its protective plastic
cap and set the cap aside for later use (wintering or
maintenance).
3 Put the probe into the probe holder or double probe
holder (depending on the options ordered) and
tighten the probe mounts to ensure watertightness.
4 Check that the probes are watertight at startup.
Seal with Teon, if required.
5 After installation, check that the probes are
constantly in contact with the pool water. When
the ltration pump is not running (even for long
periods), the water remaining in the pipes is
sufcient to protect the probes.
i
The sanitization products (acid, etc.) must be
injected last on the water return line, after any
equipment (heater, cell, etc.). Seal with Teon.
i
All types of acid (sulphuric, hydrochloric or a blend)
are compatible. We recommend using sulphuric
acid.
Always begin the calibration procedure with a calibration reset.
3
The default value is 7.2.
6. CONNECTING AND CONFIGURING PERIPHERALS
The use of dry acid such as sodium bisulfate to adjust the pH of the swimming pool is not recommended, especially in arid regions where pool water is subject to
signicant evaporation and is not commonly diluted with mains water. Dry acid can cause a build-up of by-products that can damage your chlorinator.