LUBRICATION OF THE GAS TAPS
In case of di󰀩culty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fullled
with original factory parts. The manufacturer declines any liability resulting from the
non-compliance of this obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H 3+
(Countries CZ)
G30/G31
28-30/37 mbar
G20
20 mbar
Cat: II 2H3B/P
(Countries CZ - SK)
G30/G31
30/30 mbar
G20
20 mbar
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A) 1,00 0,40 50 72 (X)
Semi-rapid (SR) 1,75 0,45 65 97 (Z)
Rapid (R) 3,00 0,75 85 128 (H3)
Double-ring compact
(DCC)
4,00 1,50 100 150 (H3)
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Double-ring compact (DCC) 8,00