Connections
The wiring must be connected to the mains
ELECTRICAL CONNECTION (FOR U.K. ONLY)
Warning - this appliance must be earthed
Further details of the power requirement of
the individual product will be found in the
users’ instruction and on the appliance rating
plate. In the case of built-in product you are
advised, should you wish to use a longer cable
than the one supplied, that a suitably rated
heat resistant type must be used.
This appliance is designed for domestic use
only. Connection to the main supply must be
made by a competant electrician, ensuring
that all current regulations concerning such
installations are observed. The appliance
must only be connected to a suitably rated
spur point, a 3 pin 13 amp plug/socket is not
suitable. A double pole switch must be
prov id ed a nd th e ci rcu it m us t hav e
appropriate fuse protection.
Note: We do not advocate the use of earth
leakage devices with electric cooking
appliances installed to spur points because of
the «nuisance tripping» which may occur. You
are again reminded that the appliance must be
correctly earthed, the manufacturer declines
any responsibility for any event occurring as a
result of incorrected electrical installation.
Check the data on the rating plate, located on
the outside of the unit, to ensure that the
supply and input voltage are suitable.
ELECTRICAL CONNECTION
Before connection, check the earthing system.
By Law, this appliance must be earthed. If this
regulation is not complied with, the
manufacturer will not be responsible for any
damage caused to persons or property. If a plug
is not already attached, fit a plug appropriate to
the load indicated on the rating plate. The earth
wire is coloured yellow/green. The plug should
always be accessible. Where the Hob is
connected direct to the electricity supply, a
circuit breaker must be fitted. If the power
supply cord is damaged this is to be replaced by
a qualied engineer so as to prevent any
potential risk. The earth wire (green and yellow
coloured) must be at least 10 mm longer than
the live and neutral wires. The section of the
cable used must be of the correct size in
relation to the absorbed power of the hob.
Please check rating plate for the power details
and ensure that the power supply cord is of the
type 3x0.75 mm² H05GG-F
If an appliance is not fitted with a supply cord
and a plug, or with other m eans for
disconnection from the supply mains having a
contact separation in all poles that provide full
disconnection under overvoltage category III
conditions, the instructions shall state that
m e a n s f o r d i s co n n e c ti on m u s t b e
incorporated in the fixed wiring in accordance
with the wiring rules.
GAS CONNECTION
These instructions are for qualified personnel,
installation of equipment must be in line with
the relevant national standard. (For U.K. only:
by law the gas installation\commissioning
must be carried out by a “Gas Safe” installer).
For liquid gas (cylinder gas) use pressure
regulators which comply with the relevant
national standards. Use only pipes,washers
and sealing washers which comply with the
relevant national standards.
All work must be carried out with the
electricity supply disconnected. The rating
plate on the hob shows the type of gas with
which it is designed to be used. Connection to
the mains gas supply or gas cylinder should be
carried out after having checked that it is
regulated for the type of gas with which it will
be supplied. If it is not correctly regulated see
the instructions in the following paragraphs to
change gas setting.
LIVE
EARTH
NEUTRAL
L
N
Power Cable
Mains Supply
Brown Wire
Green/Yellow Wire
Blue Wire