Installation Checklist
No gas leak from linesets?
Are the linesets insulated properly?
Are the connecting wirings of indoor firmly inserted
to the terminal block?
Is the connecting wiring of indoor and outdoor fixed?
Is condensate draining correctly?
Is the ground wire securely connected? Is the indoor
unit securely fixed?
Is power source voltage correct according to local
code?
Is there any odd noise?
Does the cooling temperature drop between
20-30°F?
Does the heating temperature raise between
35-40°F?
Is the room temperature display accurate?
No continuity between electrical poles?
Are refrigerant lines and electrical wire pairing is
correct?
Supply voltage is within tolerance?
Vacuum Test complete?
Extra line length refrigerant added?
Mounted level and secure?
Disconnect within view of outdoor unit?
Electrical disconnect is the correct size?
Stop valves are open fully?
Fire extinguisher on hand?
Open sources of ignition extinguished for
commissioning?
Maintenance Checklist
Seasonal coil cleanings (2x year).
Cleaning the outdoor unit air channel and inverter
heat sink/fan blades.
Inspection/maintenance of line-set insulation.
Removal of insects/foreign debris.