Haier FlexFit 3Q24FF2BEA handleiding

12 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 4 van 12
2 Zones 3 Zones 4 Zones 5 Zones
2Q20RT2BEA 3Q24RT2BEA 4Q36RT2BEA 5Q42RT2BEA
Cooling
Non-Ducted
Rated Capacity Btu/hr 18,000 24,000 36,000 42,000
Capacity Range Btu/hr 4,000-19,000 4,000-25,000 6,500-36,500 6,500-42,500
SEER2 20.6 23.0 20.5 20.5
EER2 12.3 12.2 11.0 10.5
Cooling
Ducted
Rated Capacity Btu/hr 17,000 24,000 35,000
42,000
Capacity Range Btu/hr 4,000-18,000 4,000-25,000 6,500-35,500
6,500-42,500
SEER2 17.6 17.2 17.4
17.4
EER2 10.8 10.5 10.2
10.2
Heating
Non-Ducted
Rated Heating Capacity 47°F Btu/hr 22,000 25,000 36,000 42,500
Capacity Range Btu/hr 4,000-23,000 4,000-26,000 6,500-37,000 6,500-43,500
HSPF2 (IV) 10.5 10.5 10.0 9.5
Rated Heating Capacity 5°F Btu/hr 20,000 22,800 34,000 35,000
Heating Capacity at 5F / Capacity
at 47F
91% 91% 94% 81%
COP @ 5°F / COP @ 47°F 1.8 / 3.7 1.8 / 3.6 1.8 / 3.7 1.8 / 3.6
Heating
Ducted
Rated Heating Capacity 47°F Btu/hr 22,000 26,000 35,000 42,500
Capacity Range Btu/hr 4,000-23,000 4,000-27,000 6,500-36,000 6,500-43,500
HSPF2 (IV) 10.5 10.0 10.0 9.5
Rated Heating Capacity 5°F Btu/hr 20,000 22,000 30,000 35,000
Heating Capacity at 5F / Capacity
at 47F
90% 85% 84% 83%
COP @ 5°F / COP @ 47°F 1.8 / 3.6 1.8 / 3.5 1.8 / 3.9 1.8 / 3.5
Operating
Range
Cooling °F (°C) 14~115°F (-10~46°C) 14~115°F (-10~46°C) 14~115°F (-10~46°C) 14~115°F (-10~46°C)
Heating °F (°C) -22~75°F (-30~24°C) -22~75°F (-30~24°C) -22~75°F (-30~24°C) -22~75°F (-30~24°C)
Power Supply
Voltage, Cycle, Phase V/Hz/- 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Wire Size Between IDU and ODU
14/4 AWG Stranded for L1, L2,
C, G between ODU and each
IDU; and 16/2 AWG Stranded
Shielded for H1, H2 between
ODU and nearest IDU
14/4 AWG Stranded for L1, L2,
C, G between ODU and each
IDU; and 16/2 AWG Stranded
Shielded for H1, H2 between
ODU and nearest IDU
14/4 AWG Stranded for L1, L2,
C, G between ODU and each
IDU; and 16/2 AWG Stranded
Shielded for H1, H2 between
ODU and nearest IDU
14/4 AWG Stranded for L1, L2,
C, G between ODU and each
IDU; and 16/2 AWG Stranded
Shielded for H1, H2 between
ODU and nearest IDU
Maximum Fuse Size A 30 30 40 40
Minimum Circuit Amp A 20 21 35 36
Outdoor Unit
Compressor Type DC Inverter Rotary DC Inverter Rotary DC Inverter Rotary DC Inverter Rotary
Outdoor Fan Speed RPM 250~780 250~780 250~650 250~650
Outdoor Noise Level dB 57 57 60 62
Dimension: Height in (mm) 30 1/8 (765) 30 1/8 (765) 33 1/16 (840) 33 1/16 (840)
Dimension: Width in (mm) 37 3/16 (945) 37 3/16 (945) 41 3/4 (1060) 41 3/4 (1060)
Dimension: Depth in (mm) 15 13/16 (402) 15 13/16 (402) 15 13/16 (402) 15 13/16 (402)
Weight (Net/Ship) - lbs (kg) 130/148 (59/67) 132/150 (60/68) 198/243 (90/110) 201/245 (91/111)
Basepan Heater Yes Yes Yes Yes
Refrigerant
Lines
Refrigerant R454B R454B R454B R454B
Connections Flare Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2 3/8 3/8 3/8 1/2 1/2
Factory Charge Oz 60 71 113 123
Maximum Line Length Ft / m 164/50 197/60 230/70 262/80
Maximum Height Ft / m 50/15 50/15 50/15 50/15
Minimum Line Length for Each
Individual Indoor Unit Ft / m
10/3 10/3 10/3 10/3
Maximum Line Length for Each
Individual Indoor Unit Ft / m
82/25 82/25 82/25 82/25
Maximum Line Length Without
Additional Charge Ft / m
66/20 100/30 131/40 164/50
Multi-Zone
Outdoor Unit Specications

Bekijk gratis de handleiding van Haier FlexFit 3Q24FF2BEA, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkHaier
ModelFlexFit 3Q24FF2BEA
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5489 MB