INSTALLATION INSTRUCTIONS
After the total refrigerant charge is calculated, refer to the installation instructions of the indoor unit.
Depending on the room size, a refrigerant leak sensor may need to be installed on the indoor unit.
Indoor Unit
Outdoor Unit
)
itioned
Indoor Unit
If the outdoor unit is
than one or more indoor units.
(If lower than one or more indoor units.)
Outdoor Unit
If all indoor unit are
the outdoor units.
e el
di
CAUTION
Model Number
Factory
Charge
Total Pipe
Length of
factory charge
Additional
charge rule
Branch
Maximum
pipe length
System
Maximum
pipe length
Minimum pipe length
Unit oz ft oz/ft ft ft ft
2Q18FF2B**
Refer to
rating
plate
66
0.2
65 98
10’ per indoor
3Q24FF2B** 100 82 197
4Q36FF2B** 131 82 230
2Q20RT2B** 66 82 164
3Q24RT2B** 100 82 197
4Q36RT2B** 131 82 230
5Q42RT2B** 164 82 262
Refrigerant Charge and Pipe Length Information
Installation Precautions
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type: R454B