Dry Mode (Dehumidifying Mode)
When Tai>Tset+2°C, the working mode of the indoor unit is the same as that of the cooling operation, and the fan
speed is also controlled according to the cooling mode in auto mode. The working mode sent to the outdoor unit is
cooling mode.
When Tset<Tai≤Tset+2°C, the operating mode sent by the indoor unit to the outdoor unit is dehumidication.
It is turned on for 10 minutes and the indoor unit has a low fan speed.After turning o for 6 minutes, the indoor unit stops
running. On and o will run alternately. Turn o for 6 minutes and send a shutdown signal to the outdoor unit.
When Tai ≤ Tset, the operation mode sent to the outdoor unit is shutdown.If the ambient temperature is less than
16°C, the indoor unit fan will be stopped, otherwise it will continue to blow low fan speed.
Emergency function (emergency power turn-o button)
Wired controller:The wired controller comes with a auto-restart function (not separately set)
Remote controller:on/o status, mode, fan speed, temperature setting, healthy, swing position.
If there is a timer or sleep function, it will be turned o when powered on again, and the timer and sleep
will be canceled.
Remark: Power o and power on, check if there is a wired controller, if the wired controller executes the
power-o memory of the wired controller
Forced heating/cooling modes
Dip switch setting, cooling 60HZ, heating 50HZ xed frequency operation.
Wi
For wi connections: User makes commission request(turn on the unit, set the unit into cooling mode, fan speed , and 86°F
or 30°C,) .Code writes “WiFiServiceRequest_Connect” to ERD Erd_RequestWiState.
Turn o wi module: To turn o the Wi module, regardless of what the current wi connection state is, the user needs to
press and hold the wi button for at least 3 seconds. If the WiFi module is in AP mode, connecting, reconnecting, scanning,
connected but O, or connected, a single press of the wi button must be ignored. Only if the WiFi button is pressed and
held for at least 3 seconds will the appliance initiate the o mode.