GW Instek GPP-1323 handleiding
Handleiding
Je bekijkt pagina 152 van 157

GPP-1323/GPP-1205 User Manual
152
Setting
range
33.6 V(GPP-1323)
21 V(GPP-1205)
Rise time
≤ 100 ms
Fall time
≤ 100 ms
Maximum
remote
sensing
compensati
on voltage
(single line)
0.5 V
Temperatur
e Coefficient
(TYP.)
300 ppm/℃
Current
Line
regulation
≤ 0.1 % + 3 mA
Load
regulation
≤ 0.1 % + 3 mA
Setting
range
3.15 A(GPP-1323)
5.25 A(GPP-1205)
Ripple noise
(Arms)
≤ 2 mArms
Temperatur
e Coefficient
(TYP.)
300 ppm/℃
Resolution
Voltage
programming 1 mV,readback 0.1 mV
Current
programming 0.1 mA,readback 0.01 mA
(H)
programming 10 uA,readback 1 uA (M)
programming 1 uA,readback 0.1 uA (L)
Accuracy
Setting
accuracy
Voltage: ± (0.03 % of reading + 10 mV)
Current: ± (0.3 % of reading + 10 mA) (H)
Current: ± (0.3 % of reading + 1 mA) (M)
Current: ± (0.3 % of reading + 0.1 mA) (L)
Readback
accuracy
Voltage: ± (0.03 % of reading + 10 mV)
Current: ± (0.3 % of reading + 10 mA) (H)
Current: ± (0.3 % of reading + 1 mA) (M)
Current: ± (0.3 % of reading + 0.1 mA) (L)
OVP
Setting
range
1.8 V - 35.2 V(GPP-1323)
1.0 V - 22.0 V(GPP-1205)
Bekijk gratis de handleiding van GW Instek GPP-1323, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | GW Instek |
| Model | GPP-1323 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 14224 MB |