GPP-1323/GPP-1205 User Manual
124
Output
Voltage/
Output
Current
Number of Series units:
Model
1 unit
2 units
3 units
4 units
GPP-1205
20 V /
5 A
40 V /
5 A
60 V /
5 A
80 V /
5 A
GPP-1323
32 V /
3 A
64 V /
3 A
96 V /
3 A
128 V /
3 A
Series Connection
Remote
Interface
Connection
1.Master unit connect the USB cable to the rear panel
USB A port. The other end is connected to the USB HUB
B port.
2. Slave unit connect the USB cable to the rear panel
USB B port. The other end is connected to the USB HUB
A port.
3. Set the USB Device Class setting as CDC.
4. The indicator will be shown when a remote
connection has been established.
Series
Connection
to increase
Voltage
Output