GW Instek GPE-1205 handleiding

51 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 34 van 51
GPE-1323/GPE-1205 User Manual
34
Limitations
Display
Only the master unit displays the voltage. The total
voltage is the sum of the units.
Only the master unit displays the current.
OVP/OCP
The master unit can shut down the slave unit when
OVP/OCP is tripped on the master unit (if the
slave connector is wired for shut down on alarm).
The OVP and OCP levels of the master determine
the entire OVP and OCP
Output
Voltage/
Output
Current
Model
Number of series unit :
1 unit
2 units
GPE-1323
32 V / 3 A
64 V / 3 A
GPE-1205
20 V / 5 A
40 V / 5 A
Series Output
Connection
If grounding the positive or negative terminals to the
reference ground, be sure to ground the appropriate
terminal on each unit (either positive or negative).
Series
Connection
to increase
Voltage
Output