22
40
Real time setting---Minute
Default 00, range 00~59
42
Max AC input current
3000W model:Default 15A, adjustable 5-15A
6000W model:Default 30A, adjustable 5-30A
49
Utility charging time
0000(default)
Allow utility to charge the battery all
day run.
The time allows utility to charge the
battery.
Use 4 digits to represent the time
period, the upper two digits
represent the time when utility start
to charge the battery, setting range
from 00 to 23, and the lower two
digits represent the time when utility
end to charge the battery, setting
range from 00 to 23.
(eg: 2320 represents the time allows
utility to charge the battery is from
23:00 to the next day 19:59, and the
utility charging is prohibited outside
of this period)
50
AC output time
0000(default)
Allow inverter to power the load all
day run.
The time allows inverter to power
the load.
Use 4 digits to represent the time
period, the upper two digits
represent the time when inverter
start to power the load, setting
range from 00 to 23, and the lower
two digits represent the time when
inverter end to power the load,
setting range from 00 to 23.
(eg: 2320 represents the time allows
inverter to power the load is from
23:00 to the next day 19:59, and the
inverter AC output power is
prohibited outside of this period)