Growatt SPF 3000-6000T HVM handleiding
Handleiding
Je bekijkt pagina 23 van 45

21
28
Battery equalization
voltage
Default 58.4V, 48.0V~58.4V Settable (the value should be higher than
Program 19 value)
29
Battery equalized time
Default 60min, 5min~900min Settable
30
Battery equalized timeout
Default 120min, 5min~900min Settable
31
Equalization interval
Default 1days, 1 days~90 days Settable
32
Equalization activated
immediately
Equalization activated immediately
enable
Equalization activated immediately
disable (default)
If equalization function is enabled in program 27, this program can be
setup. If “On” is selected in this program, it’s to activate battery
equalization immediately and LCD main page will shows “ ”. If “Off” is
selected, it will cancel equalization function until next activated equalization
time arrives based on program 31setting. At this time, “ ” will not be
shown in LCD main page.
36
Real time setting---Year
Default 2000, range 2000~2099
37
Real time setting---Month
Default 01, range 01~12
38
Real time setting---Date
Default 01, range 01~31
39
Real time setting---Hour
Default 00, range 00~23