AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between
inverter and AC input power source. This will ensure the inverter can be securely disconnected during
maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 40A
for SPF 3500TL HVM-Pro and 50A for SPF 5000TL HVM-Pro.
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input
and output connectors.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It’s very important for system safety and efficient operation to use appropriate cable for AC input
connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for AC wires
Model
Gauge
Torque Value
SPF 3500TL HVM-Pro
1 * 10 AWG
1.2-1.6 Nm
SPF 5000TL HVM-Pro
1 * 8 AWG
1.2-1.6 Nm
AC input/output terminal connection steps as follow:
1. Uninstall the AC terminal as above chart
2. Thread cables through pressure screw,seal ring,threaded sleeve in sequence,insert cables into connection
terminal according to polarities indicates on it and tighten the screws.
3. Push threaded sleeve on to connection terminal until both are locked tightly.