4.3 LCD parameter setting
4.3.1General settings
After pressing and holding ENTER button for 3 seconds, the unit will enter setting
mode. Press “UP” or “DOWN” button to select setting programs. Then press
ENTER” button to conrm the selection or ESC button to exit.
Program
Description
Setting Option
01
Output source
priority: To
congure load
power source
priority.
(After program
67 are enabled,
this program is
xed SUB and
cannot be set.)
Solar first
Solar energy provides power to the loads as first
priority.
If solar energy is not sucient to power all connected
loads, battery energy will supply power the loads at
the same time.
Utility provides power to the loads only when any one
condition happens:
- Solar energy is not available
- Battery voltage drops to either low-level warning
voltage or the setting point in program 12.
Utility first
Utility will provide power to the loads as first priority.
Solar and battery energy will provide power to the
loads only when utility power is not available.
SBU priority(default)
Solar energy provides power to the loads as first
priority.
If solar energy is not sucient to power all connected
loads, battery will supply power to the loads at the
same time.
Utility provides power to the loads only when battery
voltage drops to either low-level warning voltage or
the setting point in program 12.
SUB priority
Solar energy provides power to the loads as first
priority.
If solar energy is not sucient to power all connected
loads, solar and utility will power loads at the same
time.
Battery provides power to the loads only when solar
energy is not sucient and there is no utility.
02
Maximum
charging
current: set total
charging current
for solar and
utility chargers.
SPE 12000 US: Default 120A, 0A~250A Settable.
SPE 10000 US: Default 120A, 0A~220A Settable.
SPE 8000 US: Default 120A, 0A~190A Settable.
SPE 6000 US: Default 120A, 0A~140A Settable.
(Max. charging current = utility charging current +
solar charging current)
(If LI is selected in Program 5, this program can't be
set up)
03
AC input voltage
range
(After program
67 are enabled,
this program is
xed UPS and
cannot be set).
Appliance (default)
If selected, acceptable AC input voltage range will be
within:
65~140VAC
UPS
If selected, acceptable AC input voltage range will be
within:
95~140VAC
04
Power saving
mode
enable/disable
Saving mode disable (default)
If disabled, no matter connected load is low or high,
the on/off status of inverter output will not be
eected.
Saving mode enable
If enabled, the output of inverter will be off when
connected load is pretty low or not detected.
05
Battery type
AGM (default)Suitable for lead-acid battery
Items that cannot be set
19
20
21
default
56.4V
54V
42V
Items that
can be set:
default
Set range
Set requirements
02
120A
0A~250A
11
60A
0A~250A
12
46V
44~51.2V
<13 setting value
13
54v
48~58.0V
24
23