Growatt MAX 70KTL3 handleiding

35 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 35
3.3 Nameplate
Note: Other models of MAX series share the same label design with MAX50KTL3 LV,
only with different model name and parameters, detail parameter please refer to
specification in Chapter 10.
The MAX series inverter works as follows:
1>The PV panels gather solar to generate DC power to inverter.
2>With input current detection circuit, it can monitor all the PV panels' working status
and use MPPT to track the maximum power point.
3>With inverter circuit change DC power to AC power, and feed power back to grid per
grid reuqirement.
4>With output isolation relay can isolate AC output and grid, if anything goes wrong on
either inverter side or grid side, isolation relay can disconnect inverter immediately.
3.4 Working Principle
3.5 Inverter Storage
3.6 Grid Types
On-grid connection system diagram:
A B C D
Fig 3.4
symbol
A
B
C
D
PV string
Inverter
Electric meter
Gird
symbol
Description
Description
1>Do not unpack the inverter and store it in a ventilation dry place .
2>Keep the storage temperature at -25- +60and humidity at 0-95%.
3>A maximum of four inverters with package can be stacked.
4>If the inverter has been long-term stored, inspections and tests should be conducted
by qualified personnel before it is put into use.
After being stored for a month or longer, the inverter's time and date
could be wrong, you need set the time and date before using, for
more details please refer to Chapter 7.1 inverter commissioning.
The MAX series, 50-80KTL3 LV inverters connect to the grid like following drawing
3.5,60- 80KTL3 MV inverters connect to the grid like following drawing3.6,90-
100KTL3 MV inverters connect to the grid like following drawing 3.7.
400V
400V 400V
230V
230V
230V
480V
4 80V
480V
50 0V
5 0 0 V
500 V
500 V
Fig 3.5
Fig 3.6
Fig 3.7
7
8
PV voltage range
PV Isc
Max. input current
Max. apparent power
Nominal output voltage
Power factor range
Safety level
Max. output power
Max output current
Nominal output
Frequency
Ingress Protection
Model name
1100 d.c.V
55500 VA
MAX 50KTL3 LV
Class I
IP65
50000 W
0.8leading~0.8lagging
80.5 a.c.A
200-1000 d.c.V
PV Grid Inverter
50 Hz
Max.PV voltage
25 d.c.A 6
32 d.c.A 6
3W/N/PE
230 a.c.V
Operation Ambient
Temperature
-25 +60°C - °C
Made in China
VDE0126-1-1

Bekijk gratis de handleiding van Growatt MAX 70KTL3, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkGrowatt
ModelMAX 70KTL3
CategorieNiet gecategoriseerd
TaalNederlands
Grootte10147 MB