Growatt MAX 70KTL3 handleiding

35 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 32 van 35
Model
MAX
50KTL3 LV
MAX
60KTL3 LV
MAX
70KTL3 LV
MAX
80KTL3 LV
THDi
<3%
AC grid
connection type
3W/N/PE
Efficiency
Max. efficiency
98.8%
98.8%
99.0%
98.8%
Euro-eta
98.3%
98.3%
98.4%
98.3%
Protection devices
DC reverse-
polarity protection
Yes
DC switch
Yes
DC Surge
protection
Type II
Insulation
resistance
monitoring
Yes
AC surge
protection
Type II
AC short-circuit
protection
Yes
Grid monitoring
Yes
Anti-islanding
protection
Yes
Residual-current
monitoring unit
Yes
String
monitoring
Yes
Anti-PID
function
Optional
AFCI protection
Optional
General data
Dimensions (W /
H / D) in mm
860*600*300mm
Model
MAX
50KTL3 LV
MAX
60KTL3 LV
MAX
70KTL3 LV
MAX
80KTL3 LV
Input Data(DC)
Max.
recommended
PV power(for
module STC)
65000W
78000W
91000W
104000W
Max. DC voltage
1100V
Start voltage
250V
Nominal voltage
585V
585V
600V
685V
MPP voltage
range
200V-1000V
No. of MPP
trackers
6
No. of PV strings
per MPP trackers
2
Max. input current
per MPP trackers
25A
Max. short-circuit
current per MPP
trackers
32A
Output Data(AC)
AC nominal
power
50000W
60000W
70000W
80000W
Max. AC
apparent power
55500VA
66600VA
77700VA
88800VA
Nominal AC
voltage/range
230V/400V
340-440VAC
230V/400V
340-440VAC
230V/400V
340-440VAC
230V/400V
340-440VAC
AC grid
frequency/range
50/60Hz
45-55Hz/55-65Hz
Max. output
current
80.5A
96.6A
112.7A
128.8A
Power
factor(@nominal
power)
>0.99
Adjustable
power factor
0.8leading ...0.8lagging