Growatt MAX 70KTL3 handleiding

35 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 31 van 35
55
56
Warning
Description
Suggestion
Warning 100
Fan abnormal
Contact Growatt
Warning 103
NTC Broken
Contact Growatt
Warning 104
DSP and COM
firmware version
unmatch
Contact Growatt
Warning 105
Over Temperature
Contact Growatt
Warning 106
SPD abnormal
Contact Growatt
Warning 107
NE abnormal
Check if the neutral and ground cables
are well connected and firm
Warning 108
PV Circuit short
Contact Growatt
Warning 109
PV boost driver
broken
Contact Growatt
Warning 110
String abnormal
Check if the polarity is `reversed or short
Warning 111
U disk overcurrent
protection
Check if the USB port is connected to a
short circuit
NoticeMAX series inverter has three external fans and one Internal fan.
If the suggestions do not work, please contact to Growatt.
9.2.2 Error
Errors codes identify a possible equipment failure, fault or incorrect inverter setting or
configuration, any or all attempts to correct or clear a fault must be performed by
qualified personnel.
Typically, the error code can be cleared once the cause or fault is removed.
Some of error code as table shows below, may indicate a fatal error and require you to
contact the supplier or Growatt for help.
Error Code
Description
Suggestion
Error 101
Communication error
Contact Growatt
Error 102
Sample of main DSP and
slave DSP are inconsistent
Contact Growatt
Error 106
PV CurrSample Fault
Contact Growatt
Error 107
AC CurrSample Fault
Contact Growatt
Error 108
SPS Power Fault
Contact Growatt
Error 112
AFCI Fault
Contact Growatt
Error 113
IGBT drive fault
Contact Growatt
Error 114
AFCI Module check fail
Contact Growatt
Error 117
Relay fault
Contact Growatt
Error 121
CPLD abnormal
Contact Growatt
Error 122
Bus Fault
Contact Growatt
Error 124
No AC connection
Check if the mains connection/mains
voltage and frequency are correct
Error 125
PV isolation low
Check panel and line insulation to
ground is good
Error 126
Leakage current too high
Contact Growatt
Error 127
Output DC current too high
Contact Growatt
Error 128
PV voltage high
Check PV actual voltage
Error 129
Grid voltage fault
Check the actual voltage and wiring of
the grid
Error 130
Grid frequency fault
Check the actual frequency of the grid