Measurements/Tests with Test Instruments
7 Measurements/Tests with Test
Instruments
7.1 General Information
When connecting a compatible test instru-
ment, additional measurements/tests are
possible which are described in this chapter.
Important information for the performance of
measurements/tests
Attention!
!
When turning the switch, pay atten-
tion to the exact snap-in position and
the corresponding optical signals of
the LEDs, as described in these oper-
ating instructions.
The test adapter must remain connected to
the mains
for protective conductor measure-
ments (
R
PE
) at
mode 2 charging cables
by
means of the
respective test instrument.
The test adapter can remain connected
to the mains for protective conductor
measurements conducted at test
objects whose protective conductor is
not switched, as well as for insulation
measurements (Riso) with the respective
test instrument.
7.2 Measurement of Protective Conduc-
tor Resistance (R
LO
)
7.2.1 Mode 2 Charging Cable
As opposed to the usual default setting for
low-resistance measurements, the device
under test does not have to be disconnected
from all sources of voltage in this case. Both
rotary selector switches (S1 and S2) have to be
set to the
ON
and the
Status C
positions, in
order to be able to activate the test object and
switch the protective conductor through. Prior
to a protective conductor resistance measure-
ment, an offset measurement must be carried
out (the offset value of the test adapter must
be taken into account during the test).
Measurement is carried out between ICCB-
OUT1-PE and OUT2-PE.
Connect the
test object
as described in
chapter 5.3.
Connect the test object to the ICCB-IN1
PE and ICCB-OUT1 PE sockets:
PROFITEST MF XTRA, PROFITEST MF TECH,
PROFITEST MXTRA, PROFITEST MXTRA IQ,
PROFITEST MTECH+, PROFITEST MTECH+ IQ:
2-pole measuring adapter
PROFITEST PRIME, PROFITEST PRIME AC:
probes L(1) and PE(3)
SECUTEST ST PRO: 2-pole measurement
with test probes P1 and P2 (P1-P2)
Switch the test object’s ICCB on.
Perform the measurement as described
in the operating instructions for the re-
spective test instrument.
7.2.2 Mode 3 Charging Cable
The rotary selector switch must be set to
the R
ISO
position.
Connect the
test object
as described in
chapter 5.3.
Connect the test object to the ICCB-IN1
PE and ICCB-OUT1 PE sockets:
PROFITEST MF XTRA, PROFITEST MF TECH,
PROFITEST MXTRA, PROFITEST MXTRA IQ,
PROFITEST MTECH+, PROFITEST MTECH+ IQ:
2-pole measuring adapter
PROFITEST PRIME, PROFITEST PRIME AC:
probes L(1) and PE(3)
SECUTEST ST PRO: 2-pole measurement
with test probes P1 and P2 (P1-P2)
Perform the measurement as described
in the operating instructions for the re-
spective test instrument.
7.3 Measuring Insulation Resistance (R
ISO
)
Attention!
!
Insulation resistance may only be
measured at voltage-free devices!
The upper-hand rotary selector
switch must be set to the mains dis-
connect position: R
INS
Connect the test instrument to the ICCB-
IN1 socket for the mains-end of the cable
and the ICCB-OUT1 socket for the output
end of the cable of the device under test:
PROFITEST MF XTRA, PROFITEST MF TECH,
PROFITEST MXTRA, PROFITEST MXTRA IQ,
PROFITEST MTECH+, PROFITEST MTECH+ IQ:
2-pole measuring adapter
PROFITEST PRIME, PROFITEST PRIME AC:
probes L(1) and PE(3)