68
10 Technical Parameters
User Manual V1.2-2024-10-30
Technical Data GW50K07-BTC GW50K06-BTC GW100K07-BTC GW100K06-BTC
Operating
Temperature Range
(℃)
-20~+60(>45℃ derating)
Storage Temperature
(℃)
-30~+60
Relative Humidity
0~95%Non-condensing
Max. Operating
Altitude (m)
4000
Cooling Method Smart Fan Cooling
User Interface LED, LCD , WLAN+APP
Communication with
BMS
CANRS485
Communication with
Meter
RS485
Communication with
Portal
RS485,LAN
Weight (kg) 170.5 156 212 198
Dimension (W×H×D
mm)
585 x 1360 x 750
Noise Emission (dB) <68
Topology Non-isolated
Ingress Protection
Rating
IP20
DC Connector OT/DT terminal (Max. 35mm²) OT/DT terminal (Max. 70mm²)
AC Connector OT/DT terminal (Max. 35mm²) OT/DT terminal (Max. 70mm²)
Environmental
Category
3K3
Pollution Degree II
Overvoltage Category DC II / AC III
Protective Class I
Storage Temperature
(℃)
-30~+60
The Decisive Voltage
Class (DVC)
Battery: C; PV: C; AC: C; Com: A
Mounting Method Grounded
Active Anti-islanding
Method
AFDPF + AQDPF
Type of Electrical
Supply System
TN-S, TN-C, TN-C-S, TT, IT
Country of
Manufacture
China