Goodwe GW50K-SMT-L-G10 handleiding
Handleiding
Je bekijkt pagina 49 van 58

09 Maintenance
45
User Manual V1.2-2025-01-16
No. Fault Cause Solutions
52
PV Hardware
Overcurrent
Sun light is weak or
changing abnormally.
Disconnect the AC output switch and
DC input switch, then connect them 5
minutes later. Contact the dealer or the
after-sales service if the problem persists.
53
PV Software
Overcurrent
54 PV HCT Failure
Abnormal boost current
sensor
55
Cavity
Overtemperature
1. The inverter is
installed in a place
with poor ventilation.
2. The ambient
temperature exceeds
60℃.
3. A fault occurs in the
internal fan of the
inverter.
1. Check the ventilation and the ambient
temperature at the installation point.
2. If the ventilation is poor or the
ambient temperature is too high,
improve the ventilation and heat
dissipation.
3. Contact the dealer or after-sales
service if both the ventilation and the
ambient temperature are proper.